International Iron & Steel Symposium

Effect of Termite Welding Process on Residual Stress, and Wear Behaviour of R260 Quality Rail

Harun ÇUĞ M. Emre TURAN Mustafa DURSUNLAR

Abstract

-In this study, termite welding process was applied to R260 quality railway rails. Residual stress of original and termite welded rails was measured according to the DIN EN 13674-1 standard. Strain gauges were attached in the middle of the rail foot (also welded part of rail). Cutting was performed than strain values were obtained. Wear test was also performed under 50N. Results show that, residual stress was increased after the welding process and wear rate value was lower than original rails in head part of termite welded rail.



Conference
International Iron & Steel Symposium
Keywords
Rail thermite rail welding residual stress wear

Language
English

Subject
Materials Science

Full Paper (PDF)

442 views
376 downloads