2 results listed
Machining parameters for manufacturing methods can
be optimized based on the finite element method using numerical
simulation software. In this study, the simulation of the hot rolling
process was performed for plain round bar producing. Rolling
simulations were done in DEFORM-3D software and the hot
rolling process was analyzed with three different rolling
temperatures and rotation speed of rolls. In the results of
numerical analysis, diameter and circularity tolerances have been
measured for the product. The outputs of the finite element
simulation were evaluated to determine the effects of rolling
parameters on size quality of round bar product. The analysis of
variance (ANOVA) with %95 confidence level was performed in
order to determine the effect level of rolling parameters. It was
determined that the rounded product geometry is out of diameter
and circularity tolerances by increasing the rolling temperature
and the rotational speed.
International Iron & Steel Symposium
UDCS
Emre EROL
Mehmet Erdi KORKMAZ
Mustafa GÜNAY
Bu çalışmada, TiO2 nanoakışkanı kullanarak paralel akışlı
iç içe borulu eş merkezli ısı değiştiricide ısıl iletkenliğin
arttırılması amaçlanmıştır. Deney düzeneğinde saf suyun
içerisine %2 (kütle/ kütle) derişimi sağlanacak şekilde süspanse
edilen ortalama 44 nm boyutunda %97 saflıkta TiO2
nanopartikülü kullanılmıştır. Isı değiştiricide sıcak akışkan
olarak TiO2-saf su nanoakışkanı, soğuk akışkan olarak ise saf su
kullanılmıştır. Isı değiştirici paralel Sonuçlar saf su-saf su
akışkanları kullanılarak hesaplanan değerlere göre
karşılaştırılmıştır. Nanoakışkan kullanımı sonucu paralel akışlı
ısı değiştiricisinde sıcak akışkanın sahip olduğu ısı transfer
katsayısında %38, soğuk akışkanın sahip olduğu ısı transfer
katsayısında ise %3 iyileşme sağlanmıştır. Sistemin toplam ısı
transfer katsayısı %17 artmıştır.
In this study, increasing thermal performance was
objected with using TiO2 nanofluids in the parallel-flow
concentric, nested tube heat exchangers. At the experimental
setup 44 nm size and 97% purity TiO2 nanofluids was using
which is suspending at 2%(mass/mass) concentration. TiO2-pure
water nanofluids used as the hot fluid and pure water used as
cold fluid at the heat exchanger. Results were compared with
other experiment which is making by using pure water-pure
water fluids. At the parallel flow condition the heat transfer
coefficient of hot nanofluid was 38% greater than pure water
and heat transfer coefficient of cold fluid was 3% greater than
pure water. And also total heat transfer coefficient of system was
17% greater than pure water.
1.st International Conference Energy Systems Engineering
ıcese'17
Emre EROL
Tayfun MENLİK
Adnan Sözen